It would be good to know the ...
Published by Daniel Karwalski, Project Design, Project Sales, and Technical Support at Akwa-Worx Pty Ltd
It would be good to know the hydraulic flow rate you are treating and the iron removal filter size and type (i.e. manganese greensand, DMI-65, etc.). As with all media filtration processes, filtration speed and loading rates are critical to achieving adequate filter performance. Ozone is particularly effective in oxidising iron and is far more economical as far as long term operating costs when compared to liquid chlorine for oxidation purposes. Following oxidation with ozone, iron can be easily removed with media filtration. Filter rates of